Noise

From OSHKY Knowledge Library
  • OSHA uses a 5 dB doubling rate (aka, exchange rate).  For every 5dB increase, maximum time until 100% dosage halves.
  • Peak: At no point during an employee's work shift should they be exposed to a sound pressure level over 140dB C-weighted.
    • NOTE: I previously had non-weighted (otherwise known as Z-weighting) because no OSHA reference material or publications seen by me had reference to weighting as it applies to peaks. However, the ACGIH and others set this limit with C-weighting.
  • Error Factor → The error of the dosimeter must be factored in to the consideration of a violative condition.
    • For example, the dosimeters used at KYOSH are Type II dosimeters. This indicates an error of 2 dB.
    • A Type I dosimeter has an error of only 1 dB.

Noise Standards

For Noise Exposure — 1910.95(a) and (b)

  • Exchange (Doubling) Rate: 5 dB
  • Criterion Level: 90 dBA
  • Threshold: 90 dBA*

For Hearing Conservation — 1910.95(c) (General Industry amendment; not Construction)

  • Exchange (Doubling) Rate: 5 dB
  • Criterion Level: 90 dBA
  • Threshold: 80 dBA*
*See OSHA Tech Manual Section III, Chapter 5, I.A.3. and I.A.4.

Standard Threshold Shift (STS)

An STS is a change in hearing threshold relative to the baseline audiogram of an average of 10 dB or more at 2000, 3000, and 4000 Hz in either ear.

  • When a STS has occurred and the employee’s hearing level is at least 25 dB above audiometric zero in the same ear, the hearing loss is recordable on 300 logs.
  • If a STS has occurred, you set this new audiogram as the Revised Baseline Audiogram.

Sampling

Substance Codes

8111 Hearing Conservation Program (Action Level @ 50% dose / 85 dBA)
8110 Engineering Controls (PEL @ 100% dose / 90 dBA)

Edge eg5 Noise Dosimeter (3M)

Detection Management Software

This software is required when changing settings on the device, including setting date/time.  There is no way to do this from the device itself.

Procedures for setting/checking configuration

  1. Set each of the eg5 dosimeters into the charging base.
  2. Power on each dosimeter. (NOTE: Don't skip this part. Turn it on!)
  3. Ensure the USB cable is plugged into both the charging base and the computer.
  4. Open the 3M DMS software

There is a configuration file saved in the IH Shared folder on the H: drive:

H:\IH Shared\OSH Reference\Equipment\Configuration Files\Edge_Dosimeter_Config_ky.xml