Air Sampling

From OSHKY Knowledge Library
Revision as of 21:11, 17 October 2017 by Admin (talk | contribs)

Refer to OTM Section II Chapter 1 for core information.

  • Positive Pressure Respirator à Air is pushed through to the breathing zone.
  • Negative Pressure Respirator à Air is pulled by the wearer’s breathing.

Arrangements of Sampling Train

For OneNote: Explain, with pictures, the sampling train for regular setups and, especially, low-flow setups.

Charcoal Tubes

From http://www.skcinc.com/abosor.asp

  • Charcoal Tube Diagram
    Just before sampling, use a scorer/breaker tool to uniformly break the ends of the sorbent tube to a 2 mm diameter or half the diameter of the tube body.
  • Keep the tube in a vertical position during sampling to prevent the possibility of channeling that can lead to under-sampling.
  • The arrow on the tube indicates air flow direction and should point to the tube holder and pump. If no arrow is present, the smallest section should be near the tube holder.

Impinger

Video demonstrating setup and usage.

Isocyanates

Enter Isocyanate sampling methods and info about solvent stability.

Mold Sampling

Method

Time 2 Hours
Media MCEF in 37.5mm cassette
Flow Rate 2 L/min
Tubing Use a short length of tubing — just long enough to be able to flex and point down.
  • The intake on the cassette always needs to be facing down so that other, heavier particles will not land on the filter.
  • One pump is used outside and one pump is used inside.

Notes

  • When results come back with a significantly higher fungus count (CFU/m³) for the inside as opposed to the outside count, a letter is sent to the company contact detailing the findings, the hazards, and remediation. (A template is saved in Documents.)
    • The letter is printed out and submitted in the report under the IB tab.
    • The digital original is sent to your supervisor so that it can be passed on to Jenifer for updating the date and for review by the Program Manager.
  • Click here ???? for a more in-depth discussion of spores vs. CFU.

Respirable Dust – Cyclone

Media PVC
  • Media: PVC 1.7 L/min
  • Using the Cyclone eliminates all particles but respirable particles.
  • Using anything BUT the Cyclone will give you Total Dust.

SafeLog

  • Use Form OSHA-93 Direct Reading Report.
  • Carbon Monoxide (CO) has an IDLH of 1200 ppm.
  • Nitrogen dioxide (NO2) has an IDLH of 20 ppm.
  • Make sure to set sampling parameters as follows:
  CAL LVL HI LVL STEL TWA Comments
CO 50 200 Your discretion 50  
NO₂ 25 ? 5 1 Your choice  

† NIOSH recommended values

‡ OSHA PELs

─────

Screening

  • When screening for substances with a direct read device (such as the Drager or a SafeLog), results are recorded on an OSHA-93 "Direct Reading Report" form, which details each location screened and results.
  • Additionally, an OSHA-98 "Screening Report" form should be completed for all screened substances.