Line 12: | Line 12: | ||
* '''Wet Bulb Globe Temperature Indexes (WBGI)''': Here is some information on how the different temperature indices are calculated. This will help to understand the differences between the various readings on the heat monitor: | * '''Wet Bulb Globe Temperature Indexes (WBGI)''': Here is some information on how the different temperature indices are calculated. This will help to understand the differences between the various readings on the heat monitor: | ||
− | ** Indoor or outdoors with no solar load | + | ** Indoor or outdoors with no solar load: ''WBGT'' = 0.7''NWB'' + 0.3''GT'' |
+ | ** Outdoors with solar load: ''WBGT'' = 0.7''NWB'' + 0.2''GT'' + 0.1''DB'' | ||
+ | ** where: | ||
+ | *** WBGT = Wet Bulb Globe Temperature Index | ||
+ | *** NWB = Natural Wet-Bulb Temperature | ||
+ | *** DB = Dry-Bulb (air) Temperature | ||
+ | *** GT = Globe Thermometer Temperature | ||
=== Substance Codes === | === Substance Codes === | ||
+ | [''Honestly, I'm not sure which of these we need to enter on the sampling sheets. I have yet to find anything in IMIS or a CPL that indicate which IMIS codes to use. -kbh''] | ||
+ | |||
'''8320''' Heat Stress - Dry | '''8320''' Heat Stress - Dry | ||
* Do not use anything involving the Wet Bulb (WB) | * Do not use anything involving the Wet Bulb (WB) | ||
'''8330''' Heat Stress | '''8330''' Heat Stress | ||
− | * The IMIS description indicates that this is for '''''inside''''' heat monitoring. Therefore, use the WBGT<sub>i</sub> value. | + | * The IMIS description indicates that this is for '''''inside''''' heat monitoring. Therefore, use the WBGT<sub>i</sub> value. [???] |
'''8891''' Humidity, Relative | '''8891''' Humidity, Relative | ||
Line 24: | Line 32: | ||
''NEEDS INFORMATION ON QUESTEMP 34'' | ''NEEDS INFORMATION ON QUESTEMP 34'' | ||
− | + | ||
+ | [[Category:Health]] |
Revision as of 20:38, 7 August 2017
Standards
There is no specific standard that applies to heat stress. The only citation option is a General Duty, 5(a)(1).
Sampling
Methods
Refer to the OSHA Technical Manual (OTM), Section III, Chapter 4, Sub-section IV, for heat stress sampling methods. Here are some key points:
- The wick of the natural wet bulb thermometer should be kept wet with distilled water for at least one-half hour before the temperature reading is made. It is not enough to immerse the other end of the wick into a reservoir of distilled water and wait until the whole wick becomes wet by capillarity. The wick must be wetted by direct application of water from a syringe one-half hour before each reading.
- The wick should always be clean, and new wicks should be washed before using.
- The globe thermometer should be exposed at least 25 minutes before it is read.
- A stand should be used [. . .] so that [. . .] the wet-bulb and globe thermometer are not shaded.
- Wet Bulb Globe Temperature Indexes (WBGI): Here is some information on how the different temperature indices are calculated. This will help to understand the differences between the various readings on the heat monitor:
- Indoor or outdoors with no solar load: WBGT = 0.7NWB + 0.3GT
- Outdoors with solar load: WBGT = 0.7NWB + 0.2GT + 0.1DB
- where:
- WBGT = Wet Bulb Globe Temperature Index
- NWB = Natural Wet-Bulb Temperature
- DB = Dry-Bulb (air) Temperature
- GT = Globe Thermometer Temperature
Substance Codes
[Honestly, I'm not sure which of these we need to enter on the sampling sheets. I have yet to find anything in IMIS or a CPL that indicate which IMIS codes to use. -kbh]
8320 Heat Stress - Dry
- Do not use anything involving the Wet Bulb (WB)
8330 Heat Stress
- The IMIS description indicates that this is for inside heat monitoring. Therefore, use the WBGTi value. [???]
8891 Humidity, Relative
Equipment
NEEDS INFORMATION ON QUESTEMP 34